±«Ã×ÀÕÇý¶¯Æ÷ָʾµÆÒ»Ö±ÉÁάÐ޵㣺2020Offset Measurement was not possibleÎÞ·¨½øÐÐÆ«ÒƲâÁ¿.
This error is not enabled, if the active mains rectifier unit does not determine a mains offset within 10 s, which is constantly moving in a window of 200 V.Èç¹ûÓÐÔ´Ö÷ÕûÁ÷Æ÷µ¥ÔªÃ»ÓÐÈ·¶¨10ÃëÄڵĵçÔ´Æ«ÒÆ£¬¸ÃÆ«ÒÆÔÚ200·üµÄ´°¿Ú¡£
Possible causes: ¿ÉÄܵÄÔÒò£º
There is a continuous variation of the mains offset.
µçÔ´Æ«ÒÆ´æÔÚÁ¬Ðø±ä»¯¡£
On the other hand this can also be a reference to a defective voltage measurement.
ÁíÒ»·½Ã棬ÕâÒ²¿ÉÒÔ×÷ΪÓÐȱÏݵĵçѹ²âÁ¿µÄ²Î¿¼¡£
±«Ã×ÀÕËÅ·þÇý¶¯Æ÷άÐÞ±¨¾¯´úÂ룺
CPF02£¨A/D ת»»´íÎó£© ¡ª¡ª¸Ã¹ÊÕϱíÃ÷·¢ÉúÁË A/D ת»»´íÎ󡣶ÔÇý¶¯Æ÷ÖØÐÂͨµç¡£Èç¹ûÎÊÌâÈÔÈ»´æÔÚ£¬ÇëÐÞÀí/¸ü»»Çý¶¯Æ÷¡£
CPF03£¨PWM Êý¾Ý´íÎó£© ¡ª¡ª´Ë¹ÊÕϱíʾ°üÃ×ÀÕÇý¶¯Æ÷Ó²¼þË𻵣¬´Ó¶øË𻵠PWM Êý¾Ý¡£ÐÞÀí/¸ü»»Çý¶¯Æ÷¡£
CPF06£¨EEPROM Êý¾Ý´íÎó£© ¡ª¡ª¸Ã¹ÊÕϱíÃ÷¿ØÖƵç·Ë𻵡£ÐÞÀíÇý¶¯Æ÷¡£
CPF11£¨RAM ¹ÊÕÏ£© ¡ª¡ª¹ÊÕϱíʾ RAM Ó²¼þË𻵡£ÐÞÀíÇý¶¯Æ÷¡£
CPF12£¨ÉÁ´æ¹ÊÕÏ£© ¡ª¡ª´Ë¹ÊÕϱíÃ÷Çý¶¯Æ÷µÄ ROM ÒÑË𻵻òË𻵡£ÐÞÀíÇý¶¯Æ÷¡£
CPF13£¨¿´ÃŹ·µç·Òì³££¬×ÔÕï¶ÏÎÊÌ⣩ ¡ª¡ªÕâÒâζ×ÅÄÚ²¿Ó²¼þË𻵡£ÐÞÀíÇý¶¯Æ÷¡£
CPF14£¨¿ØÖƵç·¹ÊÕÏ£¬CPU ´íÎó£© ¡ª¡ªÁíÒ»¸ö±íʾ¿ØÖƵç·Ë𻵵ĹÊÕÏ´úÂ룬ÌرðÊÇÓë CPU Ïà¹ØµÄ¡£ÐÞÀíÇý¶¯Æ÷¡£
CPF16 µ½ CPF24 ¨C ¶¼ÊǹÊÕÏ´úÂ룬±íʾÖ÷¿Ø°åË𻵡£ÐÞÀíÇý¶¯Æ÷¡£